Summary for Test 2021-07-02-28-6
Test performed: ASTM A416-15Project Information
Project Identifiers | Project ID: 215576 DEA: 051K1304 EFIS: 0518000126 |
---|---|
DIST-CO-RTE-PM | 05-SCR-9-20.0 |
Award Date | 05/17/2021 |
Closeout Date | Not set |
Work Description | Soldier pile wall |
Location Description | MP 20, 1.1 miles South of junction Rte 9 and Rte 236 |
QA Service Level | 1 (Verified on 04/07/2022) |
Sample Information
Sample Taken Date | 07/02/2021 | Sample Unique Key | 28 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/16/2021 |
Sample type | Quality Assurance | A brief description of the sample | Prestressing Strand |
The quantity of what the sample constitutes | 9 | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Don | Last name of sampler or witnessed by | Hiranaga |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Sumiden Wire | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM4 - Prestressing Strand | Comments | |
---|---|---|---|
Reel/Coil/Pack Number(s) | Number of Coils | ||
Group Number | 10972 | Strand Diameter | .6 in |
Grade | 270 | Strand Specification | ASTM A 416 |
Heat Number(s) | S0577320, S0519520, S0581520-2, S0577820, S0568620, S0574521, S0550721 | Mfg. Lot Number(s) | NA |
Manufacturer(s) | Sumiden Wire |
Test Details
DIME Sample ID: 2021-07-02-28
DIME Test ID: 2021-07-02-28-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A416-15: Standard Specification for Low-Relaxation, Seven-Wire Steel Strand for Prestressed Concrete
Test Release Date: 2021-07-27
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 07/26/2021
UTM: 120kip
Temperature: 72 f
Extensometers: no data
Num | Heat Number | Coil | Area (sqin) | Peak Load (lbf) | Load at EUL (lbf) | Chord Modulus (Msi) | Elongation (in) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | S0577820 | S379413-1 | 0.214 | 59586 | 57503.4 | 32 | 1.54 | bewing |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 7/27/2021 ✔