Summary for Test 2021-06-28-7-2
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 215145 DEA: 030H4604 EFIS: 0315000174 |
---|---|
DIST-CO-RTE-PM | 03-PLA-80-2.6/3.1 |
Award Date | 11/16/2020 |
Closeout Date | 08/24/2022 |
Work Description | WIDEN ON-RAMP AND REPLACE BRIDGE. |
Location Description | PLACER COUNTY IN ROSEVILLE AT THE ATLANTIC STREET ON RAMP |
QA Service Level | 1 (Verified on 10/05/2020) |
Sample Information
Sample Taken Date | 06/28/2021 | Sample Unique Key | 7 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/29/2021 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 concrete cylinders |
The quantity of what the sample constitutes | 6 cylinders | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Raymond | Last name of sampler or witnessed by | Macy |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Lehigh | Transportation Laboratory (TL) Number | 174463 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Girder stems A/B/C and stage 1 soffit and end/intermediate |
Material Information
Material Type | Concrete | The concrete mix design number | Z78D9A1 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | Unknown | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | Truck chute | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-06-28-7
DIME Test ID: 2021-06-28-7-2
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2021-07-26
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: SA
Date of test: 07/26/2021
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 6.00 in
Average diameter of cylinder 2: 6.00 in
Maximum load on cylinder 1: 217808 lbf
Maximum load on cylinder 2: 208520 lbf
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Age of specimen: 28 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 7703.0 psi
Compressive strength of cylinder 2: 7375.0 psi
Compressive strength (to nearest 10 psi): 7540 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Bluehill Data Point FileTest graph for Cylinder Code 1 of 2
Source: Bluehill Data Point File
Test graph for Cylinder Code 2 of 2
Test was verified on 7/26/2021 ✔