Summary for Test 2021-06-22-47-1
Test performed: CONCLP 4-16
Warning: The test results shown on this page have been superseded and are invalid.
This information is for reference only.
Please click this
link
to view the corrected test.
Project Information
Project Identifiers | Project ID: 213856 DEA: 112888U4 EFIS: 1118000199 |
---|---|
DIST-CO-RTE-PM | 11-SD-11,125,905-Various |
Award Date | 05/09/2019 |
Closeout Date | 09/14/2023 |
Work Description | CONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY |
Location Description | SAN DIEGO COUNTY AT VARIOUS LOCATIONS |
QA Service Level | 1 (Verified on 07/19/2019) |
Sample Information
Sample Taken Date | 06/22/2021 | Sample Unique Key | 47 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/02/2021 |
Sample type | Authorization | A brief description of the sample | HMWM |
The quantity of what the sample constitutes | 1 Quart Can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Rob | Last name of sampler or witnessed by | Johnson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Transpo Industries Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Methacrylate | Mfg. Lot Number(s) | B0623217010 |
---|---|---|---|
Batch number | B0623217010 | Mix number | 3529 |
Test Details
DIME Sample ID: 2021-06-22-47
DIME Test ID: 2021-06-22-47-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2021-07-21
Test Results
Input Type: Calculated
Tester's full name: Spencer Adams
Date of test: 07/21/2021
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 23.6
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 1.01
Volatile content (ASTM D 2369) 30% max: 28
Flash point (ASTM D 3828) more than 180 deg F: 190
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: no data
Tack free time, 400 minutes max: 392
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/21/2021 ✔
Warning: The test results shown on this page have been superseded and are invalid.