Summary for Test 2015-08-12-1-1
Test performed: ASTM C39-17aProject Information
Project Identifiers | Project ID: 209139 DEA: 071170U4 EFIS: 0700000085 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-33.2/37.2 |
Award Date | 02/10/2014 |
Closeout Date | 03/01/2022 |
Work Description | CONSTRUCT HOV LANES, WIDEN BRIDGES, AND REALIGN RAMPS. |
Location Description | LOS ANGELES COUNTY IN BALDWIN PARK AND WEST COVINA FROM 0.1 MILE WEST OF PUENTE AVENUE UNDERCROSSING TO 0.2 MILE EAST OF HOLLENBECK STREET UNDERCROSSING |
QA Service Level | 1 (Verified on 05/06/2014) |
Sample Information
Sample Taken Date | 08/12/2015 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/13/2015 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | nelson | Last name of sampler or witnessed by | pereira |
Title of sampler | asr | Telephone number of sampler | Unknown |
Laboratory sample identification | 882-63 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | job | Transportation Laboratory (TL) Number | 847863 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | retaining wall on route 10 |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | cm5645 |
---|---|---|---|
The truck number from where the sample was collected | 603 | The batch plant ticket number from where the sample was collected | load19 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | truck | Where the material sample would have been placed if not sampled | Unknown |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-08-12-1
DIME Test ID: 2015-08-12-1-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM C39-17a: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-08-26
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 08/26/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.98 in
Average diameter of cylinder 2: 5.98 in
Maximum load on cylinder 1: 98610 lb
Maximum load on cylinder 2: 101100 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Age of specimen: 14 days
Age of specimen in hours: no data
Cross sectional area of cylinder 1: 28.09 in^2
Cross sectional area of cylinder 2: 28.09 in^2
Compressive strength of cylinder 1: 3510.5 psi
Compressive strength of cylinder 2: 3599.1 psi
Compressive strength (to nearest 10 psi): 3550 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/26/2015 ✔