Summary for Test 2021-06-30-24-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 06/30/2021 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/08/2021 |
Sample type | Verification | A brief description of the sample | PG64-16/PG64-10 Asphalt Binder |
The quantity of what the sample constitutes | 5 Cans | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Gustavo | Last name of sampler or witnessed by | Moreno |
Title of sampler | Telephone number of sampler | 999 999 9999 | |
Laboratory sample identification | 063021-129 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | World Oil | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 10027 | |
Time of sample | 1230AM | HMA Supplier | |
Certified Asphalt Supplier | Lunday Thagard Company-World Oil - South Gate CA | Multigrade | Yes |
Multigrade Type | PG 64-16 / PG 64-10 | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-30-24
DIME Test ID: 2021-06-30-24-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-07-15
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 07/13/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 170.016 grams
Mass of empty container #2: 167.486 grams
Mass of container #1 before test (m1i): 205.609 grams
Mass of container #2 before test (m2i): 203.68 grams
Mass of container #1 after test (m1f): 205.6 grams
Mass of container #2 after test (m2f): 203.672 grams
Average mass change: -0.024 percent
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 7/15/2021 ✔