Summary for Test 2021-06-09-29-5
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 993103 DEA: 021J7504 EFIS: 0220000124 |
---|---|
DIST-CO-RTE-PM | 02-LAS-36-14.5/16.8 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Devil's Corral Safety |
Location Description | Not set |
QA Service Level | 1 (Verified on 08/02/2021) |
Sample Information
Sample Taken Date | 06/09/2021 | Sample Unique Key | 29 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/10/2021 |
Sample type | Preliminary | A brief description of the sample | 2 Bags Soil |
The quantity of what the sample constitutes | Structural Section Recomendation | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Steiner |
Title of sampler | AAME | Telephone number of sampler | |
Laboratory sample identification | D78837 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Not applicable | Transportation Laboratory (TL) Number | 824588 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | Not Applicable |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | 02-LAS-36-14.5 on Shoulder 20 ft past EP |
Where the material sample would have been placed if not sampled |
Test Details
DIME Sample ID: 2021-06-09-29
DIME Test ID: 2021-06-09-29-5
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-12-24
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/21/2021
Minimum soil resistance of the lab measurement: 2600 Ohms
Soil sample temperature: 24.9 C
Soil box constant: 1
pH of soil: 6.03
Minimum soil resistance corrected to 15.5: 3211.00 Ohm-cm
Minimum soil resistivity at 15.5: 3211 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/24/2021 ✔