Summary for Test 2021-06-14-21-2

Test performed: AASHTO T315-16

Project Information

Project IdentifiersProject ID: 215415
DEA: 101L2204
EFIS: 1020000125
DIST-CO-RTE-PM10-AMA-88-14.4/15.0,16.7/17.0
Award Date02/11/2021
Closeout Date08/30/2021
Work DescriptionCOLD PLANE, AND OVERLAY WITH HMA.
Location DescriptionAMADOR COUNTY IN AND NEAR JACKSON FROM BROADWAY TO 0.1 MILE EAST OF COURT STREET AND FROM ROCKY CREEK BRIDGE TO 0.1 MILE EAST OF DALTON ROAD
QA Service Level1 (Verified on 02/01/2021)

Sample Information

Sample Taken Date06/14/2021 Sample Unique Key21
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/21/2021
Sample typeDepartment Acceptance A brief description of the sampleASPHALT BINDER
The quantity of what the sample constitutes1 OF 1 CAN From where was the sample collectedSource
First name of sampler or witnessed byJ Last name of sampler or witnessed byDEHOFF
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameMARATHON ELK GROVE Transportation Laboratory (TL) Number760563
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number Tank number
Time of sample HMA SupplierGEORGE REED INC
Certified Asphalt SupplierMarathon Petroleum Co. LP - Elk Grove CA MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-06-14-21
DIME Test ID: 2021-06-14-21-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-06-29

Test Results


Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/24/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.167 kPa
Phase Angle (δ) (for the 10 cycles): 87.3 degree
Complex Modulus (G*) (for the 10 measurements): 1.395 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.40 kPa
General comments (publicly viewable) (Max 1000 characters): ORIG

Test was verified on 6/29/2021