Summary for Test 2021-06-02-23-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 215245 DEA: 021J4504 EFIS: 0220000080 |
---|---|
DIST-CO-RTE-PM | 02-SIS-89-14.0/19.0 |
Award Date | 12/08/2020 |
Closeout Date | 09/27/2021 |
Work Description | PLACE HMA (TYPE A). |
Location Description | SISKIYOU COUNTY ABOUT 6 MILES NORTH OF BARTLE FROM 0.4 MILE NORTH OF EDISON CREEK ACCESS ROAD TO 2.0 MILES SOUTH OF MUD CREEK BRIDGE |
QA Service Level | 1 (Verified on 10/23/2020) |
Sample Information
Sample Taken Date | 06/02/2021 | Sample Unique Key | 23 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/17/2021 |
Sample type | Acceptance | A brief description of the sample | ASPHALT BINDER |
The quantity of what the sample constitutes | 1 of 4 cans | From where was the sample collected | Source |
First name of sampler or witnessed by | RANDY | Last name of sampler or witnessed by | UNKNOWN |
Title of sampler | CGI | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | VALERO | Transportation Laboratory (TL) Number | 858982 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-34 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | JF SHEA FAWNDALE | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-06-02-23
DIME Test ID: 2021-06-02-23-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-06-23
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Ruben Macias
Date of test: 06/22/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 156.013 grams
Mass of empty container #2: 158.383 grams
Mass of container #1 before test (m1i): 205.600 grams
Mass of container #2 before test (m2i): 208.200 grams
Mass of container #1 after test (m1f): 205.300 grams
Mass of container #2 after test (m2f): 207.900 grams
Average mass change: -0.604 percent
General comments (publicly viewable) (Max 1000 characters): Per 2018 Standard Specifications
Test was verified on 6/23/2021 ✔