Summary for Test 2021-05-26-43-1
Test performed: CTM 643-April 2020Project Information
Project Identifiers | Project ID: 215814 DEA: 023H3204 EFIS: 0217000097 |
---|---|
DIST-CO-RTE-PM | 02-SIS-5-2.7/R15.9 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Dunsmuir GAP - Pavement Rehabilitation. |
Location Description | Not set |
QA Service Level | 1 (Verified on 08/02/2021) |
Sample Information
Sample Taken Date | 05/26/2021 | Sample Unique Key | 43 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/27/2021 |
Sample type | Preliminary | A brief description of the sample | Soil |
The quantity of what the sample constitutes | 1 Container for Culvert Recommendation | From where was the sample collected | Source |
First name of sampler or witnessed by | Dan | Last name of sampler or witnessed by | Curran |
Title of sampler | MREA | Telephone number of sampler | |
Laboratory sample identification | D78810 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Unknown | Transportation Laboratory (TL) Number | 897758 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | 02-SIS 5 PM 8.67 SB On Ramp 0.5 ft Depth |
Where the material sample would have been placed if not sampled | 02 SIS 5 |
Test Details
DIME Sample ID: 2021-05-26-43
DIME Test ID: 2021-05-26-43-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: CTM 643-April 2020: Method for Test for Laboratory Resistivity and pH for Soil and Water
Test Release Date: 2021-08-06
Test Results
The test method used?: Laboratory Resistivity Test for Soil (pH and Resistivity)
Input Type: Measured
Tester's full name: Darrell Valasek
Date of test: 06/14/2021
Minimum soil resistance of the lab measurement: 12250 Ohms
Soil sample temperature: 20.9 C
Soil box constant: 1
pH of soil: 6.30
Minimum soil resistance corrected to 15.5: 13903.75 Ohm-cm
Minimum soil resistivity at 15.5: 13904 Ohm-cm
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/6/2021 ✔