Summary for Test 2021-05-18-48-2
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 215033 DEA: 033H6504 EFIS: 0318000027 |
---|---|
DIST-CO-RTE-PM | 03-NEV-49-8.3/8.7 |
Award Date | 08/07/2020 |
Closeout Date | 09/23/2021 |
Work Description | CONSTRUCT A TWO-WAY LEFT-TURN LANE AND 8' SHOULDERS. |
Location Description | NEVADA COUNTY ON ROUTE 49 FROM 0.1 MILE SOUTH OF ROUND VALLEY ROAD TO 0.1 MILE NORTH OF QUAIL CREEK DRIVE |
QA Service Level | 1 (Verified on 06/22/2020) |
Sample Information
Sample Taken Date | 05/18/2021 | Sample Unique Key | 48 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/11/2021 |
Sample type | Department Acceptance | A brief description of the sample | binder |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | JD | Last name of sampler or witnessed by | Akinson |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero | Transportation Laboratory (TL) Number | 928874 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | Knife River | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-05-18-48
DIME Test ID: 2021-05-18-48-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-06-24
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 06/16/2021
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.188 kPa
Phase Angle (δ) (for the 10 cycles): 85.7 degree
Complex Modulus (G*) (for the 10 measurements): 1.569 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.57 kPa
General comments (publicly viewable) (Max 1000 characters): Per 2018 standard specifications ORIG
Test was verified on 6/24/2021 ✔