Summary for Test 2021-06-14-3-4
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 213750 DEA: 120K0224 EFIS: 1214000097 |
---|---|
DIST-CO-RTE-PM | 12-ORA-5-14.5/17.1 |
Award Date | 03/05/2019 |
Closeout Date | Not set |
Work Description | South County Improvement Project (Phase 2 - Oso/Alicia) CONST BRIDGES, RW, SW, HMA PVMT, JPCP, DRAINAGE, AND ELECT SYSTEMS. |
Location Description | ORANGE COUNTY IN MISSION VIEJO AND LAGUNA HILLS FROM 0.7 MILE SOUTH OF OSO PARKWAY OVERCROSSING TO 0.3 MILE SOUTH OF ALICIA PARKWAY OVERCROSSING |
QA Service Level | 1 (Verified on 04/15/2019) |
Sample Information
Sample Taken Date | 06/14/2021 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/15/2021 |
Sample type | Quality Assurance | A brief description of the sample | #5 2'-8" Welded Hoops |
The quantity of what the sample constitutes | 100 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Brandon | Last name of sampler or witnessed by | Quintana |
Title of sampler | Telephone number of sampler | 8582850576 | |
Laboratory sample identification | Sequoia Lab | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 1202019459 |
Hoop Manufacturer Lot Number(s) | 11 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #5 |
Diameter of Hoop | 2'-8" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor Utah |
Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-06-14-3
DIME Test ID: 2021-06-14-3-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-06-16
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: bewing
Date of test: 06/16/2021
UTM: 400kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 3 | 11 | 5/16mm | 0.31 | 27124.03 | 87497 | Ok Necking | bewing |
General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 6/16/2021 ✔