Summary for Test 2021-05-18-44-1

Test performed: AASHTO T48-18

Project Information

Project IdentifiersProject ID: 44444
DEA: ASCP
EFIS: ASCP
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for submitting Sample information for Asphalt Supplier Certification Program.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date05/18/2021 Sample Unique Key44
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/18/2021
Sample typeQuality Control A brief description of the samplePG70-10 Asphalt Binder
The quantity of what the sample constitutes1 of 2 cans From where was the sample collectedManufacturer
First name of sampler or witnessed byDon Last name of sampler or witnessed byConner
Title of sampler Sr Asphalt Technician Telephone number of sampler6614327352
Laboratory sample identificationPG7010-210518 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSan Joaquin Refinery, Bakersfield, CA Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 70-10
ModifiedNo Lot number
Sublot number Tank number9001
Time of sample HMA Supplier
Certified Asphalt SupplierSan Joaquin Refinery - Bakersfield CA MultigradeNo
Multigrade TypeNot set Asphalt Binder Mix NumberNot set

Test Details

DIME Sample ID: 2021-05-18-44
DIME Test ID: 2021-05-18-44-1
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2021-06-10

Test Results


Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Celsius and mmHg
Input Type: Calculated
Tester's full name: Don Conner
Date of test: 05/18/2021
Observed Flash Point: 318 C
Ambient Barometric Pressure: 755 mmHg
Cleveland Open-Cup Flash Point in Celsius: 318 C
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 6/10/2021