Summary for Test 2021-05-27-2-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 212252
DEA: 033F5604
EFIS: 0313000033
DIST-CO-RTE-PM03-SUT,YUB-20-17.0/17.1,0.0/0.4
Award Date02/11/2021
Closeout Date01/25/2023
Work DescriptionINSTALL CAST-IN-STEEL SHELL CONCRETE PILE.
Location DescriptionSUTTER AND YUBA COUNTIES IN YUBA CITY AND MARYSVILLE AT THE FEATHER RIVER BRIDGE AND OVERHEAD
QA Service Level1 (Verified on 04/27/2018)

Sample Information

Sample Taken Date05/27/2021 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing05/31/2021
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes3220 From where was the sample collectedFabricator
First name of sampler or witnessed bySteve Last name of sampler or witnessed byHall
Title of samplerCT METS QA INSPECTOR Telephone number of sampler6466327821
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTNT Rebar Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL134-088-21 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingProduction Testing
Service or UltimateUltimate Rebar Heat Number(s)3500015581
Hoop Manufacturer Lot Number(s)1, 6, 11, 16, 21 and 22 Material Standard CodeASTM A706
Material Grade60 Rebar Size#6
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerNucor Seattle
Welding CompanyTNT Rebar Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2021-05-27-2
DIME Test ID: 2021-05-27-2-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-06-07

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: spaine
Date of test: 06/07/2021
UTM: 400kip
Temperature: 72 f
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12166/19mm0.4442435.7596445Ok Neckingspaine

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
Test graph for the Sample

Test was verified on 6/7/2021