Summary for Test 2021-04-04-2-7
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 04/04/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/07/2021 |
Sample type | Verification | A brief description of the sample | PG58-16/PG58-22 |
The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | ERIC | Last name of sampler or witnessed by | Gauss |
Title of sampler | COC Program | Telephone number of sampler | |
Laboratory sample identification | 040421-751752 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Valero Wilmington | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | TK8 | |
Time of sample | 7:00am | HMA Supplier | |
Certified Asphalt Supplier | Valero Marketing & Supply - Wilmington CA | Multigrade | Yes |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-04-2
DIME Test ID: 2021-04-04-2-7
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-05-28
Test Results
Phase: PAV residue
Input Type: Measured
Tester's full name: Eva Torres
Date of test: 05/24/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 53.137 kPa
Phase Angle (δ) (for the 10 cycles): 43.8 degree
Complex Modulus (G*) (for the 10 measurements): 5313.792 kPa
Test Temperature (Specimen 1): 25.0 C
(G*) x sin(δ)=: 3678 kPa
General comments (publicly viewable) (Max 1000 characters): PAV 2ND +6
Test was verified on 5/28/2021 ✔