Summary for Test 2021-04-27-25-3

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 213746
DEA: 080Q75U4
EFIS: 0817000114
DIST-CO-RTE-PM08-SBD,RIV-60-R4.6/R9.9, R0.0/12.2
Award Date04/18/2019
Closeout Date06/28/2022
Work DescriptionREPLACEMENT OF TWO OUTSIDE LANES AND CONCRETE SLABS
Location DescriptionNot set
QA Service Level1 (Verified on 06/17/2019)

Sample Information

Sample Taken Date04/27/2021 Sample Unique Key25
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing04/28/2021
Sample typeDepartment Acceptance A brief description of the sampleConcrete beams
The quantity of what the sample constitutes3 beams From where was the sample collectedJob Site
First name of sampler or witnessed byRMA Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification87-2A,87-2B, 87-2C Linked DIME Sample ID
The fabricator/manufacturer/facility nameRV Concrete Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberRVC-60-3
The truck number from where the sample was collected The batch plant ticket number from where the sample was collectedTT1
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedOn Job Site at Concrete Truck Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2021-04-27-25
DIME Test ID: 2021-04-27-25-3
Testing Lab: CT D08 - Fontana Field Testing Laboratory
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2021-05-10

Test Results


Number of specimens: 1
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: No
Input Type: Calculated
Tester's full name: M. Warde, K. Patel
Date of test: 05/07/2021
Identification number: 87-2C
Width of specimen: 5.9375 inch
Depth of specimen: 6.125 inch
Span length of specimen: 18 inch
Maximum load applied: 7590 lb
Curing history and apparent moisture condition of the specimen: sand pit
If specimen was capped, ground or if leather shims were used: yes
Defects in specimen, including numbers of beams discarded during test: none
Age of specimen: 10 days
Age of specimen in hours: no data
Modulus of rupture: 640 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 5/10/2021