Summary for Test 2021-05-01-1-1
Test performed: ASTM C1064-17Project Information
Project Identifiers | Project ID: 214422 DEA: 040J6424 EFIS: 0414000476 |
---|---|
DIST-CO-RTE-PM | 04-SON-101-32.8/R54.2 |
Award Date | 12/24/2019 |
Closeout Date | Not set |
Work Description | CRACK, SEAT AND OVERLAY WITH RHMA AND HMA, AND REPLACE CULVERTS. |
Location Description | SONOMA COUNTY AT VARIOUS LOCATIONS FROM LIMERICK LANE OVERCROSSING TO ROUTE 101/128 SEPARATION |
QA Service Level | 1 (Verified on 09/23/2019) |
Sample Information
Sample Taken Date | 05/01/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/01/2021 |
Sample type | Quality Control | A brief description of the sample | SCC concrete |
The quantity of what the sample constitutes | 2.8 CY | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Avery | Last name of sampler or witnessed by | Flores |
Title of sampler | Quality Control Manager | Telephone number of sampler | (925) 525-8562 |
Laboratory sample identification | 21089 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Oldcastle Infrastructure | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | 04-son-101-32.8/R54.2 | |
Structure name | State Hwy in Sonoma County 101/128 Separation |
Material Information
Material Type | Concrete | The concrete mix design number | 55 |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 91572 | |
Concrete batch plant | Oldcastle Infrastructure | The fabricator/manufacturer designation for the sample | Mix no. 55 |
A detailed description of where the material sample was collected | Travelling Bucket | Where the material sample would have been placed if not sampled | RBC |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2021-05-01-1
DIME Test ID: 2021-05-01-1-1
Testing Lab: Oldcastle Precast, Incorporated - Pleasanton
Test Method: ASTM C1064-17: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
Test Release Date: 2021-05-03
Test Results
Input Type: Calculated
Tester's full name: Avery Flores
Date of test: 05/01/2021
Temperature: 72 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/3/2021 ✔