Summary for Test 2021-04-16-6-4
Test performed: AASHTO T315-16Project Information
Project Identifiers | Project ID: 215405 DEA: 032G1604 EFIS: 0320000235 |
---|---|
DIST-CO-RTE-PM | 03-YOL-45-0.6/12.9 |
Award Date | 02/16/2021 |
Closeout Date | 06/30/2021 |
Work Description | COLD PLANE AC PAVEMENT AND REPLACE WITH HOT MIX ASPHALT. |
Location Description | YOLO COUNTY NEAR KNIGHTS LANDING FROM SYCAMORE SLOUGH BRIDGE TO YOLO COUNTY LINE ROAD |
QA Service Level | 1 (Verified on 01/18/2021) |
Sample Information
Sample Taken Date | 04/16/2021 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/16/2021 |
Sample type | Department Acceptance | A brief description of the sample | Binder |
The quantity of what the sample constitutes | 1 of 1 can | From where was the sample collected | Source |
First name of sampler or witnessed by | Sam | Last name of sampler or witnessed by | Mosallono |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Marathon | Transportation Laboratory (TL) Number | 783753 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | 1 |
Sublot number | 8 | Tank number | |
Time of sample | HMA Supplier | Teichert Hollwood | |
Certified Asphalt Supplier | Marathon Petroleum Co. LP - Elk Grove CA | Multigrade | No |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-04-16-6
DIME Test ID: 2021-04-16-6-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2021-04-27
Test Results
Phase: PAV residue
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 04/26/2021
Test Plate Diameter: 8 mm
Test Gap: 2 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 1.00 %
Stress Amplitude: 101.379 kPa
Phase Angle (δ) (for the 10 cycles): 40.0 degree
Complex Modulus (G*) (for the 10 measurements): 10139.097 kPa
Test Temperature (Specimen 1): 28.0 C
(G*) x sin(δ)=: 6517 kPa
General comments (publicly viewable) (Max 1000 characters): per 2018 standard specifications
Test was verified on 4/27/2021 ✔