Summary for Test 2021-01-06-2-7
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 01/06/2021 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/23/2021 |
Sample type | Recertification | A brief description of the sample | A706 Gr 60 Flash Welded Hoop |
The quantity of what the sample constitutes | 10 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Arthur | Last name of sampler or witnessed by | Peterson |
Title of sampler | CT QA METS Inspector | Telephone number of sampler | 707-342-8602 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | CMC Rebar San Bernardino | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L110-001-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 3098556 |
Hoop Manufacturer Lot Number(s) | NA | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #7 |
Diameter of Hoop | 5'-0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | CMC Steel California |
Welding Company | CMC Rebar San Bernardino | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-01-06-2
DIME Test ID: 2021-01-06-2-7
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2021-04-27
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 04/20/2021
UTM: 400kip
Temperature: 72.00 f
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 7 | No. 7/22mm | 1 | 0.6 | 58196 | 96993 | OK Necking | fsaylor |
General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 4/27/2021 ✔