Summary for Test 2021-04-06-1-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 215063 DEA: 032F5704 EFIS: 0300020615 |
---|---|
DIST-CO-RTE-PM | 03-PLA-80-46.3/63.5 |
Award Date | 09/23/2020 |
Closeout Date | 08/11/2023 |
Work Description | Replace 4 Bridges (OC) on Highway 80 from Crystal Springs to Cisco Grove (Baxter, Drum Forebay) |
Location Description | Not set |
QA Service Level | 1 (Verified on 11/16/2020) |
Sample Information
Sample Taken Date | 04/06/2021 | Sample Unique Key | 1 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/07/2021 |
Sample type | Quality Assurance | A brief description of the sample | #9 Button Head Galvanized |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Other |
First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
Title of sampler | ASI | Telephone number of sampler | 916-826-6371 |
Laboratory sample identification | Linked DIME Sample ID | 2021-03-25-3 | |
The fabricator/manufacturer/facility name | Pacific Galvanizing | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B22-014-21 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Headed Bars | Production or Authorization Testing | Retest |
---|---|---|---|
Rebar Heat Number(s) | 4101383 | Head Manufacturer Lot Number(s) | A204230 A202389 |
Rebar Size | #9 | Headed Bar Model Name | GripTwist and Grip Twist Doughnut 10Ab |
Size of Head | Full Size - 9x | Head Connection Type | Friction Weld |
Head Shape | Circular | Rebar Manufacturer | CMC |
Head Manufacturer | Barsplice | Head Fabricator | Camblin Steel |
Material Standard Code | ASTM A706 | Headed Bar Unique ID | Not set |
Test Details
DIME Sample ID: 2021-04-06-1
DIME Test ID: 2021-04-06-1-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2021-04-08
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 04/08/2021
UTM: 400kip
Temperature: 72.00 f
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 2 | No. 9/29mm | 1 | 1 | 91717 | 91717 | End Anchor | fsaylor |
General comments (publicly viewable) (Max 1000 characters): End Anchor; OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 4/8/2021 ✔