Summary for Test 2015-07-01-3-1
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 208642 DEA: 07252004 EFIS: 0712000074 |
---|---|
DIST-CO-RTE-PM | 07-LA-405-39.4/48.6 |
Award Date | 06/28/2013 |
Closeout Date | 08/25/2016 |
Work Description | REPLACE CONC PAVEMENT WITH PRECAST PRESTRESSED CONC PAVEMENT. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM ROUTE 405/101 SEPARATION TO ROUTE 405/5 SEPARATION |
QA Service Level | 1 (Verified on 08/13/2013) |
Sample Information
Sample Taken Date | 07/01/2015 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/07/2015 |
Sample type | Quality Assurance | A brief description of the sample | Concrete Cylinder 6 x 12 |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Addis | Last name of sampler or witnessed by | Ambaye |
Title of sampler | Structure Representative | Telephone number of sampler | Unknown |
Laboratory sample identification | 910-01 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Associate Ready Mix | Transportation Laboratory (TL) Number | 150701 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Austin Vault Slab and RW |
Material Information
Material Type | Concrete | The concrete mix design number | 557237 |
---|---|---|---|
The truck number from where the sample was collected | 2 | The batch plant ticket number from where the sample was collected | Not provided |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | TRUCK | Where the material sample would have been placed if not sampled | Slab and RW |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-07-01-3
DIME Test ID: 2015-07-01-3-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-07-09
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 07/08/2015
Average diameter of cylinder 1: 6.02 in
Average diameter of cylinder 2: 6.02 in
Maximum load on cylinder 1: 95850 lb
Maximum load on cylinder 2: 91120 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 7 days
Cross sectional area of cylinder 1: 28.46 in^2
Cross sectional area of cylinder 2: 28.46 in^2
Compressive strength of cylinder 1: 3367.9 psi
Compressive strength of cylinder 2: 3201.7 psi
Compressive strength (to nearest 10 psi): 3280 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/9/2015 ✔