Summary for Test 2021-03-12-17-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 214395 DEA: 103A7204 EFIS: 1013000259 |
---|---|
DIST-CO-RTE-PM | 10-MER-99-20.1/24.3 |
Award Date | 12/12/2019 |
Closeout Date | 08/23/2023 |
Work Description | PLACE CRCP AND HMA. |
Location Description | MERCED COUNTY IN AND NEAR ATWATER FROM 0.4 MILE SOUTH OF BUHACH OVERCROSSING TO 0.8 MILE NORTH OF WEST ATWATER OVERHEAD |
QA Service Level | 1 (Verified on 09/13/2019) |
Sample Information
Sample Taken Date | 03/12/2021 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/02/2021 |
Sample type | Department Acceptance | A brief description of the sample | Asphalt |
The quantity of what the sample constitutes | 1 of 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | M | Last name of sampler or witnessed by | Cozad |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Santa Fe Winton hma | Transportation Laboratory (TL) Number | c034082 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 70-10 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Marathon Petroleum Co. LP - Elk Grove CA | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-03-12-17
DIME Test ID: 2021-03-12-17-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-04-06
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Erika Gonzalez
Date of test: 04/05/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 171.651 grams
Mass of empty container #2: 175.680 grams
Mass of container #1 before test (m1i): 207.091 grams
Mass of container #2 before test (m2i): 210.830 grams
Mass of container #1 after test (m1f): 206.960 grams
Mass of container #2 after test (m2f): 210.697 grams
Average mass change: -0.374 percent
General comments (publicly viewable) (Max 1000 characters): Per 2018 standard specifications
Test was verified on 4/6/2021 ✔