Summary for Test 2021-03-23-14-8
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 214795 DEA: 030H3424 EFIS: 0317000153 |
---|---|
DIST-CO-RTE-PM | 03-SAC-99-22.6 |
Award Date | 11/13/2020 |
Closeout Date | 03/03/2022 |
Work Description | REPLACE BRIDGE DECK WITH PRESTRESSED CONCRETE BOX GIRDER. |
Location Description | SACRAMENTO COUNTY IN SACRAMENTO AT 21ST AVENUE UNDERCROSSING |
QA Service Level | 1 (Verified on 03/12/2020) |
Sample Information
Sample Taken Date | 03/23/2021 | Sample Unique Key | 14 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 03/23/2021 |
Sample type | Quality Assurance | A brief description of the sample | Galvanized rebar with welded wire mesh |
The quantity of what the sample constitutes | 8 of 192 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Brandon | Last name of sampler or witnessed by | Miller |
Title of sampler | SR | Telephone number of sampler | 9165056839 |
Laboratory sample identification | 001 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Confab Lathrop - KRC Vernalis | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name | 21st Avenue UC |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Service | Rebar Heat Number(s) | 2012525 |
Hoop Manufacturer Lot Number(s) | 1 and 2 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #5 |
Diameter of Hoop | 0'-0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Vinton Steel |
Welding Company | Pacific Galvanizing | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2021-03-23-14
DIME Test ID: 2021-03-23-14-8
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2021-03-29
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/29/2021
UTM: 75kip
Temperature: 72 f
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 4 | 2 | 5/16mm | 0.31 | 31251.40 | 100811 | Broke a way From Wire | fsaylor |
General comments (publicly viewable) (Max 1000 characters): Broke a way From Wire
Test Graph
Source: Bluehill Data Point FileTest graph for the Sample
Test was verified on 3/29/2021 ✔