Summary for Test 2021-03-04-17-1
Test performed: AASHTO T240-17Project Information
Project Identifiers | Project ID: 213700 DEA: 020H9004 EFIS: 0215000077 |
---|---|
DIST-CO-RTE-PM | 02-BUT-70-41.9/42.3 |
Award Date | 05/07/2020 |
Closeout Date | 11/01/2021 |
Work Description | REMOVE CULVERTS AND CONSTRUCT BRIDGE |
Location Description | BUTTE COUNTY NEAR PULGA FROM 2.5 MILES WEST OF PENSTOCK UNDERCROSSING TO 2.1 MILES WEST OF PENSTOCK UNDERCROSSING |
QA Service Level | 1 (Verified on 01/03/2019) |
Sample Information
Sample Taken Date | 03/04/2021 | Sample Unique Key | 17 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/22/2021 |
Sample type | Acceptance | A brief description of the sample | Asphalt Binder Modified |
The quantity of what the sample constitutes | 2 of 2 cans | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Monte | Last name of sampler or witnessed by | Spencer |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Marathan | Transportation Laboratory (TL) Number | 896989 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Asphalt Binder Supplier | Marathon Petroleum Co. LP - Bakersfield CA | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-03-04-17
DIME Test ID: 2021-03-04-17-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T240-17: Standard Method of Test for Effect of Heat and Air on a Moving Film of Asphalt Binder (Rolling Thin-Film Oven Test)
Test Release Date: 2021-03-26
Test Results
Is mass change based on one or two containers?: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 03/24/2021
Any material loss from containers during heating process/testing?: No
Mass of empty container #1: 172.660 grams
Mass of empty container #2: 171.198 grams
Mass of container #1 before test (m1i): 209.330 grams
Mass of container #2 before test (m2i): 207.552 grams
Mass of container #1 after test (m1f): 209.116 grams
Mass of container #2 after test (m2f): 207.326 grams
Average mass change: -0.603 percent
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs
Test was verified on 3/26/2021 ✔