Summary for Test 2021-03-18-8-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 213856
DEA: 112888U4
EFIS: 1118000199
DIST-CO-RTE-PM11-SD-11,125,905-Various
Award Date05/09/2019
Closeout Date09/14/2023
Work DescriptionCONSTRUCT FREEWAY TO FREEWAY CONNECTORS AND 4-LANE HIGHWAY FACILITY
Location DescriptionSAN DIEGO COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date03/18/2021 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/23/2021
Sample typeQuality Assurance A brief description of the sample#14 Grip-Twist Couplers
The quantity of what the sample constitutes150 Couplers From where was the sample collectedFabricator
First name of sampler or witnessed byWade Last name of sampler or witnessed byDurant
Title of samplerSR Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameIntegrity Rebar Transportation Laboratory (TL) NumberC692457
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#14 Coupler ModelGrip-Twist
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A203090 Male, A193235 Female Rebar Heat Number(s)3101019
Rebar Size 2 Coupler Unique IDNot set

Test Details

DIME Sample ID: 2021-03-18-8
DIME Test ID: 2021-03-18-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2021-03-24

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 03/24/2021
UTM: 2000kip
Temperature: 72.00 f
Halo ID: Large
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
11No. 14/43mm1-0.00942.2521686796385OK Neckingfsaylor

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 3/24/2021