Summary for Test 2021-02-01-32-2
Test performed: AASHTO T51-13Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 02/01/2021 | Sample Unique Key | 32 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/10/2021 |
Sample type | Verification | A brief description of the sample | Asphalt Binder |
The quantity of what the sample constitutes | 1 can | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Valorie | Last name of sampler or witnessed by | Rice |
Title of sampler | COC Program | Telephone number of sampler | |
Laboratory sample identification | 5822-0057 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Valero Benicia | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 58-22 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | 2B | |
Time of sample | 0600 | HMA Supplier | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | Not set |
Multigrade Type | Not set | Asphalt Binder Mix Number | Not set |
Test Details
DIME Sample ID: 2021-02-01-32
DIME Test ID: 2021-02-01-32-2
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-13: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2021-03-19
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: Two
Input Type: Measured
Tester's full name: Harish Thakur
Date of test: 03/17/2021
Ductility of test #1 (D1): 115 cm
Ductility of test #2 (D2): 120 cm
Ductility of sample: 118 cm
General comments (publicly viewable) (Max 1000 characters): as per 2018 standard specs
Test was verified on 3/19/2021 ✔