Summary for Test 2020-06-04-42-6

Test performed: AASHTO T324-14
Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.

Project Information

Project IdentifiersProject ID: 212535
DEA: 031A9204
EFIS: 0300020608
DIST-CO-RTE-PM03-SUT-20-5-11.3
Award Date06/11/2019
Closeout Date12/01/2021
Work DescriptionSUTTER BYPASS WIDENING AND REHAB
Location DescriptionNEAR YUBA CITY FROM SUTTER BYPASS TO 0.1 MILE WEST OF LYTLE ROAD.
QA Service Level1 (Verified on 07/23/2018)

Sample Information

Sample Taken Date06/04/2020 Sample Unique Key42
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/05/2020
Sample typeVerification A brief description of the sample3/4 " RHMA-G
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byBrad Last name of sampler or witnessed byMcKeehan (WITNESS)
Title of samplerKRC Personnel Telephone number of sampler
Laboratory sample identificationJMF20-023B Linked DIME Sample ID
The fabricator/manufacturer/facility nameKRC Hallwood Transportation Laboratory (TL) NumberC693829
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-04-42
DIME Test ID: 2020-06-04-42-6
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T324-14: Standard Method of Test for Hamburg Wheel-Track Testing of Compacted Asphalt Mixtures (Hamburg Wheel Track)
Test Release Date: 2021-02-23

Test Results


Input Type: Calculated
Tester's full name: Kavon Rastegar
Date of test: 07/06/2020
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth average: no data
Impression at specified number of passes average: no data
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel A): 25000
Specified minimum number of passes at ½” rut depth, or number of passes at ½” rut depth if applicable (Wheel B): 25000
Impression at specified number of passes, or specified maximum impression if applicable (Wheel A): 3.89 mm
Impression at specified number of passes, or specified maximum impression if applicable (Wheel B): 5.98 mm
Stripping Inflection Point (Wheel A): 25000
Stripping Inflection Point (Wheel B): 25000
General comments (publicly viewable) (Max 1000 characters): JMF20-023B. Jeff Herbert

Test was verified on 2/23/2021

Warning: The test results shown on this page have been superseded and are invalid. This information is for reference only.