Summary for Test 2020-06-04-42-3
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 212535 DEA: 031A9204 EFIS: 0300020608 |
---|---|
DIST-CO-RTE-PM | 03-SUT-20-5-11.3 |
Award Date | 06/11/2019 |
Closeout Date | 12/01/2021 |
Work Description | SUTTER BYPASS WIDENING AND REHAB |
Location Description | NEAR YUBA CITY FROM SUTTER BYPASS TO 0.1 MILE WEST OF LYTLE ROAD. |
QA Service Level | 1 (Verified on 07/23/2018) |
Sample Information
Sample Taken Date | 06/04/2020 | Sample Unique Key | 42 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/05/2020 |
Sample type | Verification | A brief description of the sample | 3/4 " RHMA-G |
The quantity of what the sample constitutes | JMF Verification | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Brad | Last name of sampler or witnessed by | McKeehan (WITNESS) |
Title of sampler | KRC Personnel | Telephone number of sampler | |
Laboratory sample identification | JMF20-023B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | KRC Hallwood | Transportation Laboratory (TL) Number | C693829 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-04-42
DIME Test ID: 2020-06-04-42-3
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2021-02-23
Test Results
Number of tests: 1
What is the unit of measurement for theoretical density?: US Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Kavon Rastegar
Date of test: 07/01/2020
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7346.7 grams
Mass of oven-dry sample in air for Sample 1: 2146.0 grams
Mass of container filled with the sample and water for Sample 1: 8628.3 grams
Temperature of Water: 76 °F
Specific Gravity for Sample 1: 2.483
Theoretical maximum density at 25°C (77°F): no data
General comments (publicly viewable) (Max 1000 characters): JMF20-023B. Report only.
Test was verified on 2/23/2021 ✔