Summary for Test 2015-05-04-5-3
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 209240 DEA: 07259204 EFIS: 0700020196 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-R8.8/13.5 |
Award Date | 03/10/2014 |
Closeout Date | 04/11/2017 |
Work Description | CONSTRUCT AUSTIN VAULT SAND FILTER BEDS. |
Location Description | LOS ANGELES COUNTY IN LOS ANGELES FROM LA CIENEGA BOULEVARD TO 0.3 MILE WEST OF VERMONT AVENUE |
QA Service Level | 1 (Verified on 04/18/2014) |
Sample Information
Sample Taken Date | 05/04/2015 | Sample Unique Key | 5 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/06/2015 |
Sample type | Quality Control | A brief description of the sample | 6x12 |
The quantity of what the sample constitutes | 6 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | C | Last name of sampler or witnessed by | TONG |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | 903-04 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | JOB | Transportation Laboratory (TL) Number | 150504 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | AVSF |
Structure name | AVSF FOOTING AT LOCATION 10 |
Material Information
Material Type | Concrete | The concrete mix design number | 556300 |
---|---|---|---|
The truck number from where the sample was collected | 464 | The batch plant ticket number from where the sample was collected | 658 |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | CHUTE | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-05-04-5
DIME Test ID: 2015-05-04-5-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-06-01
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 06/01/2015
Average diameter of cylinder 1: 6 in
Average diameter of cylinder 2: 6 in
Maximum load on cylinder 1: 128740 lb
Maximum load on cylinder 2: 126700 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 4553.9 psi
Compressive strength of cylinder 2: 4481.8 psi
Compressive strength (to nearest 10 psi): 4520 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 6/1/2015 ✔