Summary for Test 2021-01-28-8-4

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 99999
DEA: 0322222
DIST-CO-RTE-PM03-SAC,OMG-888,99,80-0.6-0.6
Award DateNot set
Closeout DateNot set
Work DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
Location DescriptionTHIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES.
QA Service Level (Verified on 04/05/2013)

Sample Information

Sample Taken Date01/28/2021 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing01/29/2021
Sample typeVerification A brief description of the sample1/2" Type A HMA w 15% RAP
The quantity of what the sample constitutes12 boxes From where was the sample collectedManufacturer
First name of sampler or witnessed byJane Last name of sampler or witnessed byDoe
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameSyar Industries Inc Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2021-01-28-8
DIME Test ID: 2021-01-28-8-4
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-01-29

Test Results


What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Clinton Edmiston
Date of test: 01/29/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1647.7 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1519.9 g
Correction Factor (Percent by mass of HMA Specimen): 1.79 %
Moisture Content: 0.21 %
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.76 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 1/29/2021