Summary for Test 2021-01-28-8-4
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 99999 DEA: 0322222 |
---|---|
DIST-CO-RTE-PM | 03-SAC,OMG-888,99,80-0.6-0.6 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
Location Description | THIS PROJECT RECORD WAS ADDED FOR DIME TESTERS - DATA SUBMITTED FOR THIS PROJECT SHOULD NOT BE USED FOR ANY OTHER PURPOSES. |
QA Service Level | (Verified on 04/05/2013) |
Sample Information
Sample Taken Date | 01/28/2021 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/29/2021 |
Sample type | Verification | A brief description of the sample | 1/2" Type A HMA w 15% RAP |
The quantity of what the sample constitutes | 12 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jane | Last name of sampler or witnessed by | Doe |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Syar Industries Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2021-01-28-8
DIME Test ID: 2021-01-28-8-4
Testing Lab: CT HQ - Sacramento Hot Mix Asphalt Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2021-01-29
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Clinton Edmiston
Date of test: 01/29/2021
Test procedure used?: Method A
Mass of the specimen basket assembly: no data
Mass of the specimen and specimen basket assembly prior to ignition: no data
Mass of HMA Sample prior to ignition: 1647.7 g
Mass Loss: no data
Mass of aggregate remaining after ignition: 1519.9 g
Correction Factor (Percent by mass of HMA Specimen): 1.79 %
Moisture Content: 0.21 %
Temperature Compensation Factor: no data
Test Temperature: no data
Corrected Asphalt Binder Content: 5.76 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/29/2021 ✔