Summary for Test 2021-01-25-9-1
Test performed: ASTM A370-15Project Information
Project Identifiers | Project ID: 214300 DEA: 07343404 EFIS: 0718000018 |
---|---|
DIST-CO-RTE-PM | 07-LA-39-31.2 |
Award Date | 10/30/2019 |
Closeout Date | Not set |
Work Description | IN LOS ANGELES COUNTY, ON ROUTE 39 AT NORTH FORK SAN GABRIEL RIVER BRIDGE (BR. NO. 53-3069) REPLACE BRIDGE |
Location Description | IN LOS ANGELES COUNTY ABOUT 19 MILES NORTH OF AZUSA AT NORTH FORK SAN GABRIEL RIVER BRIDGE |
QA Service Level | 1 (Verified on 12/20/2019) |
Sample Information
Sample Taken Date | 01/25/2021 | Sample Unique Key | 9 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 01/29/2021 |
Sample type | Quality Assurance | A brief description of the sample | Coupon Casting |
The quantity of what the sample constitutes | 2 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Debbie | Last name of sampler or witnessed by | Ozuna |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Goldens Foundary | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | SMTL TM6 - Ductile Iron Cast Samples | Heat Number (s) | 0111 |
---|---|---|---|
Part Number (s) | 68 31 246 | Material Specification | A536 |
Grades | 65-45-12 | Metal Foundry Manufacturer (Mill) | Goldens Foundary |
Prestressing Manufacturer | DSI |
Test Details
DIME Sample ID: 2021-01-25-9
DIME Test ID: 2021-01-25-9-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM A370-15: Standard Test Methods and Definitions for Mechanical Testing of Steel Products (Tensile - Round Sample)
Test Release Date: 2021-02-02
Test Results
Number of Samples: 2
Input Type: Calculated
Tester's full name: fsaylor
Date of test: 01/29/2021
UTM: 67kip
Temperature: 72 F
Num | Sample | Heat Number | Diameter (in) | Area (sqin) | Stress at Offset (psi) | Tensile Strength (psi) | Elongation in 4 x d (%) | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 0111 | 0.496 | 0.19322 | 51483 | 80461 | 15 | fsaylor | |
2 | 0111 | 0.496 | 0.19322 | 51441 | 80674 | 16 | fsaylor |
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Test was verified on 2/2/2021 ✔