Summary for Test 2020-12-11-4-4
Test performed: ASTM E23-12cProject Information
Project Identifiers | Project ID: 214579 DEA: 010B0904 EFIS: 0100020444 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-8.2/8.7 |
Award Date | 04/21/2020 |
Closeout Date | Not set |
Work Description | Panther Creek & Hunter Creek Bridges |
Location Description | DEL NORTE COUNTY NEAR KLAMATH AT PANTHER CREEK BRIDGE AND AT HUNTER CREEK BRIDGE |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 12/11/2020 | Sample Unique Key | 4 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 12/14/2020 |
Sample type | Department Acceptance | A brief description of the sample | 1 1/2" A709 Gr 50 plate |
The quantity of what the sample constitutes | 1 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | kevin | Last name of sampler or witnessed by | muser |
Title of sampler | qa | Telephone number of sampler | 19165170532 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Thompson Metal Fab | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | S19-650-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM6 - Steel Check Sample Plate | Heat Number(s) | 2504752 |
---|---|---|---|
Material Specification | A709 | Grade | 50 |
Thickness | 1.5 | Shape | plate |
Metal Foundry Manufacturer (Mill) | Nucor | Plate Dimension | 96x480 |
Test Details
DIME Sample ID: 2020-12-11-4
DIME Test ID: 2020-12-11-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM E23-12c: Standard Test Methods for Notched Bar Impact Testing of Metallic Materials (Charpy Impact)
Test Release Date: 2021-01-27
Test Results
Input Type: Measured
Tester's full name: Joshua Gallaway
Date of test: 01/13/2021
Temperature Required: 40 oF
Minimum Energy Required: 25 ftlb
Test Temperature 1: 40 oF
Impact Energy 1: 49.34 ftlb
Impact Energy 2: 16.09 ftlb
Impact Energy 3: 54.28 ftlb
Striker Radius: 8
Average Impact Energy: 40 ftlb
Value Exceeds The Machine Capacity?: No
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 1/27/2021 ✔