Summary for Test 2020-06-27-7-5

Test performed: AASHTO T283-14

Project Information

Project IdentifiersProject ID: 213411
DEA: 030H10U4
EFIS: 0317000246
DIST-CO-RTE-PM03-SAC-5-9.7/24.9
Award Date05/01/2019
Closeout Date02/22/2024
Work DescriptionNot set
Location DescriptionConstruction on state highway in Sacramento County in and near Sacramento from 1.1 miles south of Elk Grove Boulevard to American River Viaduct
QA Service Level1 (Verified on 07/19/2019)

Sample Information

Sample Taken Date06/27/2020 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/01/2020
Sample typeVerification A brief description of the sample3/4" HMA - A w/RAP (Long Life, RB, #2)
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byJ. Buscheck (WITNESS) Last name of sampler or witnessed byJ. Buscheck (WITNESS)
Title of samplerGranite Personnel Telephone number of sampler
Laboratory sample identificationJMF20-033 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGranite -- Bradshaw Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-06-27-7
DIME Test ID: 2020-06-27-7-5
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T283-14: Standard Method of Test for Resistance of Compacted Asphalt Mixtures to Moisture-Induced Damage (Moisture Content)
Test Release Date: 2021-01-20

Test Results


Unit system used?: SI Units
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 10/01/2020
Specimen Treatment: Untreated
Average Dry Tensile Strength: 168 psi
Average Wet Tensile Strength: 121 psi
Tensile Strength Ratio: 72
General comments (publicly viewable) (Max 1000 characters): JMF20-033. Test date estimated.

Test was verified on 1/20/2021