Summary for Test 2015-04-07-2-2
Test performed: CTM 521-November 2014Project Information
Project Identifiers | Project ID: 208862 DEA: 080K7104 EFIS: 0800000366 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15,215-14.0/R16.4,16.0/17.8 |
Award Date | 11/13/2012 |
Closeout Date | 02/13/2017 |
Work Description | I-15/I-215 Interchange Improvements (Devore) |
Location Description | On I-15 from 0.8 mile south of Glen Helen Parkway UC to 1.4 mile north of Kenwood Ave UC And On I-215 from 1.2 mile south of Devore Road OC to the I-15 junction |
QA Service Level | 1 (Verified on 06/10/2013) |
Sample Information
Sample Taken Date | 04/07/2015 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/09/2015 |
Sample type | Quality Control | A brief description of the sample | Concrete Cylinders |
The quantity of what the sample constitutes | 4 | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Edward | Last name of sampler or witnessed by | Mu |
Title of sampler | ASR | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | site | Transportation Laboratory (TL) Number | 20150705 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Unknown |
Structure name | Unknown |
Material Information
Material Type | Concrete | The concrete mix design number | ct1c4500di |
---|---|---|---|
The truck number from where the sample was collected | 47 | The batch plant ticket number from where the sample was collected | np |
Concrete batch plant | Unknown | The fabricator/manufacturer designation for the sample | Unknown |
A detailed description of where the material sample was collected | bridge 24 deck | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-04-07-2
DIME Test ID: 2015-04-07-2-2
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: CTM 521-November 2014: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2015-05-19
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Matthew Clayton
Date of test: 05/19/2015
Average diameter of cylinder 1: 6 in
Average diameter of cylinder 2: 6 in
Maximum load on cylinder 1: 166570 lb
Maximum load on cylinder 2: 165980 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Age of specimen: 42 days
Cross sectional area of cylinder 1: 28.27 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Compressive strength of cylinder 1: 5892.1 psi
Compressive strength of cylinder 2: 5871.2 psi
Compressive strength (to nearest 10 psi): 5880 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 5/19/2015 ✔