Summary for Test 2020-08-12-47-4

Test performed: AASHTO T269-14

Project Information

Project IdentifiersProject ID: 214899
DEA: 033H4504
EFIS: 0318000001
DIST-CO-RTE-PM03-ED-50-33.8/34.2
Award Date07/29/2020
Closeout DateNot set
Work DescriptionCONSTRUCT RW, WIDEN RDWY, COLD PLANE AC PVMT, & HMA OVERLAY.
Location DescriptionEL DORADO COUNTY AT FRESH POND FROM 0.6 TO 0.2 MILE WEST OF FOREST ROAD/OUTER LIMITS LANE
QA Service Level1 (Verified on 04/15/2020)

Sample Information

Sample Taken Date08/12/2020 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/13/2020
Sample typeVerification A brief description of the sample3/4 inch HMA - A
The quantity of what the sample constitutesJMF Verification From where was the sample collectedManufacturer
First name of sampler or witnessed byJames Last name of sampler or witnessed byBrewster (WITNESS)
Title of samplerTeichert Personnel Telephone number of sampler
Laboratory sample identificationJMF20-034 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Aggresgates - Grantline Plant Transportation Laboratory (TL) NumberC788460
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix NumberNot set

Test Details

DIME Sample ID: 2020-08-12-47
DIME Test ID: 2020-08-12-47-4
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T269-14: Standard Method of Test for Percent Air Voids in Compacted Dense and Open Asphalt Mixtures (Air Void)
Test Release Date: 2020-12-16

Test Results


Number of tests: 3
Is the sample lab compacted or field compacted?:
Input Type: Calculated
Tester's full name: Jeff Herbert
Date of test: 08/28/2020
Percent Air Voids: 3 %
Percent Air Voids 2: 3.4
Percent Air Voids 3: 3.1
Average Percent Air Voids: 3.2
General comments (publicly viewable) (Max 1000 characters): JMF20-034. Test date estimated.

Test was verified on 12/16/2020