Summary for Test 2020-11-30-3-6
Test performed: ASTM B499-14Project Information
Project Identifiers | Project ID: 212085 DEA: 07296604 EFIS: 0713000057 |
---|---|
DIST-CO-RTE-PM | 07-LA-10-14.0/19.0 |
Award Date | 06/04/2018 |
Closeout Date | 05/04/2023 |
Work Description | PAINT AND REHABILITATE BRIDGE - (STRAIN (PAINT AND INSTALL CATWALK) |
Location Description | IN THE CITY OF LOS ANGELES, AT SANTA MONICA VIADUCT (BR. NO. 53-1301). PAINT AND REHABILITATE BRIDGE |
QA Service Level | 1 (Verified on 07/25/2018) |
Sample Information
Sample Taken Date | 11/30/2020 | Sample Unique Key | 3 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 12/03/2020 |
Sample type | Quality Assurance | A brief description of the sample | ASTM A449 Bolt Assembly |
The quantity of what the sample constitutes | 328 | From where was the sample collected | Distributor |
First name of sampler or witnessed by | Brian | Last name of sampler or witnessed by | Murray |
Title of sampler | QA Inspector | Telephone number of sampler | 213 435 4055 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Page Industrial | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L140-313-20 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | Nut Mfg. Lot Number(s) | NU 700957 | |
Washer Mfg. Lot Number(s) | NLRPR3914 | Bolt Specification | ASTM 449-14 |
Bolt Length(s) | 3 1/2" | Nut Specification | SAE J995-79 |
Washer Specification | F436-2004 | Finish | Hot Dipped Galvanized |
Diameter/Size | 1/4" | Bolt Mfg. Lot Number | 684424 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2020-11-30-3
DIME Test ID: 2020-11-30-3-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM B499-14: Standard Test Method for Measurement of Coating Thicknesses by the Magnetic Method: Nonmagnetic Coatings on Magnetic Basis Metals (Coating)
Test Release Date: 2020-12-14
Test Results
Input Type: Calculated
Tester's full name: Fred Saylor
Date of test: 12/09/2020
Sample No.: 1A
Rocap Number: no data
Heat Number(s): no data
Mfg. Lot Number: 684424
Finish Coating: ASTM F2329 - Hot Dip
Product Markings: no data
Size: .250 in
Bolt Length: 3.5 in
Measurement Average: 3.6 mils
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/14/2020 ✔