Summary for Test 2015-03-31-2-3
Test performed: ASTM C39-10Project Information
Project Identifiers | Project ID: 7285 DEA: 040120T4 EFIS: 0400000027 |
---|---|
DIST-CO-RTE-PM | 04-SF-80-12.6/13.9 |
Award Date | 11/27/2012 |
Closeout Date | Not set |
Work Description | CONSTRUCT BRIDGE, ROADWAYS, ELECTRICAL, BUILDINGS AND REMOVE BRIDGES |
Location Description | THE CITY AND COUNTY OF SAN FRANCISCO FROM THE YERBA BUENA TUNNEL TO 1.3 KM EAST OF THE YERBA BUENA TUNNEL |
QA Service Level | 1 (Verified on 10/29/2012) |
Sample Information
Sample Taken Date | 03/31/2015 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 04/10/2015 |
Sample type | Authorization | A brief description of the sample | 5 cylinders for trial batch |
The quantity of what the sample constitutes | 5 cylinders | From where was the sample collected | Source |
First name of sampler or witnessed by | Chetan | Last name of sampler or witnessed by | Sihra |
Title of sampler | TE Civil | Telephone number of sampler | 5108676025 |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | Central Plant | Transportation Laboratory (TL) Number | Unknown |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Trial Batch for 28 Days |
Structure name | YBITS2 28 MPa |
Material Information
Material Type | Concrete | The concrete mix design number | D20PP5E1 |
---|---|---|---|
The truck number from where the sample was collected | 1253 | The batch plant ticket number from where the sample was collected | 18994996 |
Concrete batch plant | 12 | The fabricator/manufacturer designation for the sample | Class 2 WR |
A detailed description of where the material sample was collected | Wheel Barrow from Chute | Where the material sample would have been placed if not sampled | Not set |
From Lot No. | Not set | Bag Lot No. | Not set |
Test Details
DIME Sample ID: 2015-03-31-2
DIME Test ID: 2015-03-31-2-3
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: ASTM C39-10: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2015-04-28
Test Results
Unit system used?: US Units
Number of specimens: 5
Test performed: With no density determined
Input Type: Measured
Tester's full name: Mullins
Date of test: 04/28/2015
Capped in accordance with?: ASTM C617/CTM521
Average diameter of cylinder 1: 5.99 in
Average diameter of cylinder 2: 6.00 in
Average diameter of cylinder 3: 6.01 in
Average diameter of cylinder 4: 6.01 in
Average diameter of cylinder 5: 6.00 in
Maximum load on cylinder 1: 128594 lb
Maximum load on cylinder 2: 122641 lb
Maximum load on cylinder 3: 127539 lb
Maximum load on cylinder 4: 123739 lb
Maximum load on cylinder 5: 133790 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Type of fracture pattern of cylinder 4: 1
Type of fracture pattern of cylinder 5: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: no data
Correction factor for cylinder 3: no data
Correction factor for cylinder 4: no data
Correction factor for cylinder 5: no data
Age of specimen: 28 days
Cross sectional area of cylinder 1: 28.18 in^2
Cross sectional area of cylinder 2: 28.27 in^2
Cross sectional area of cylinder 3: 28.37 in^2
Cross sectional area of cylinder 4: 28.37 in^2
Cross sectional area of cylinder 5: 28.27 in^2
Compressive strength of cylinder 1: 4563.3 psi
Compressive strength of cylinder 2: 4338.2 psi
Compressive strength of cylinder 3: 4495.6 psi
Compressive strength of cylinder 4: 4361.6 psi
Compressive strength of cylinder 5: 4732.6 psi
Compressive strength (to nearest 10 psi): 4500 psi
General comments (publicly viewable) (Max 1000 characters):
Test Graph
Source: Partner Data Point FileTest graph for Cylinder Code 1 of 5
Source: Partner Data Point File
Test graph for Cylinder Code 2 of 5
Source: Partner Data Point File
Test graph for Cylinder Code 3 of 5
Source: Partner Data Point File
Test graph for Cylinder Code 4 of 5
Source: Partner Data Point File
Test graph for Cylinder Code 5 of 5
Test was verified on 4/28/2015 ✔