Test 2020-11-20-8-2 (CTM 670-December 2013) Summary

Project Information
Project IdentifiersProject ID: 212657
DEA: 024G5004
EFIS: 0214000031
DIST-CO-RTE-PM02-TRI-299-1.9-2.3
Work DescriptionVIADUCT WIDENING
Location DescriptionTRINITY COUNTY NEAR SALYER FROM 0.1 MILE EAST TO 0.6 MILE EAST OF WHITE HOUSE GULCH ROAD
Sample Information
Sample Taken Date11/20/2020 Sample Unique Key8
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/24/2020
Sample typeQuality Assurance A brief description of the sampleBar Lock Coupler
The quantity of what the sample constitutes4 lots From where was the sample collectedJob Site
First name of sampler or witnessed byValerie Last name of sampler or witnessed byTownsley
Title of samplerASR Laboratory sample identification
The fabricator/manufacturer/facility nameDayton Superior Transportation Laboratory (TL) NumberC758146
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerNucor
Coupler ManufacturerDayton Superior Intermediate Assembler or Fabricator
Rebar Size#9 Coupler ModelD250L Bar Lock
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)177052 Rebar Heat Number(s)3500005995
Rebar Size 2
Test Details
DIME Sample ID: 2020-11-20-8
DIME Test ID: 2020-11-20-8-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2020-12-02
Test Results

Number of Samples Tested: 1
Input Type: Measured
Tester's full name: fsaylor
Date of test: 12/01/2020
UTM:400kip
Temperature:72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 9/29mm1019793897938Service Splicefsaylor

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 12/02/2020