Test 2013-07-16-1374-2 (CTM 217-June 2011) Summary

The test has been saved successfully.
Project Information
Project IdentifiersProject ID: 8127
DEA: 080N5904
EFIS: 0800000533
DIST-CO-RTE-PM08-SBD-40-R85.2
Work DescriptionCONSTRUCT PC/PS BULB-TEE GIRDER BRIDGE
Location DescriptionSAN BERNARDINO COUNTY NEAR ESSEX AT VAN WINKLE WASH BRIDGE
Sample Information
Sample Taken Date7/16/2013 Sample Unique Key1374
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/17/2013
Sample typeQuality Control A brief description of the sampleWashed Concrete Sand at 150 yards
The quantity of what the sample constitutes1 bag From where was the sample collectedSource
First name of sampler or witnessed byJared Last name of sampler or witnessed byTietjen
Title of samplerField Technician Laboratory sample identificationNot set
The fabricator/manufacturer/facility nameHigh Grade Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifierNot set
Structure nameNot set
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)Washed Concrete Sand
The fabricator's/manufacturer's product name for the sampleNot set The fabricator/manufacturer designation for the sampleNot set
The plant numberNot set A detailed description of where the material sample was collectedHigh Grade Batch Plant
Where the material sample would have been placed if not sampledNot set Primary Aggregate Nominal Size
The concrete mix design number Lot numberNot set
Sublot numberNot set HMA Design ID
Test Details
DIME Sample ID: 2013-07-16-1374
DIME Test ID: 2013-07-16-1374-2
Testing Lab: SCST, LLC.
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2013-07-19
Test Results

Number of tests: 1
Input Type: Calculated
Tester's full name: Tony Stewart
Date of test: 07/17/2013
Temperature correction:no data
Temperature of solution:no data
Clay reading (test 1):no data
Sand reading (test 1):no data
Sand equivalent (test 1):no data
Sand equivalent before temperature correction:no data
Sand equivalent after temperature correction:86
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/19/2013