Test 2020-09-21-27-6 (AASHTO T176-08) Summary

Project Information
Project IdentifiersProject ID: 212872
DEA: 07302204
EFIS: 0713000481
DIST-CO-RTE-PM07-VEN-126-0.0/R13.6
Work DescriptionPLACE HOT MIX ASPHALT AND INDIVIDUAL SLAB REPLACEMENT.
Location DescriptionVENTURA COUNTY IN VENTURA AND SANTA PAULA FROM ROUTE 126/101 SEPARATION TO HAUN CREEK BRIDGE
Sample Information
Sample Taken Date9/21/2020 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/25/2020
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 0.5% LAS
The quantity of what the sample constitutes10 Bags Of Agg., 1 Bag Of Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byMichael Last name of sampler or witnessed byBrook
Title of sampler Laboratory sample identification0552-20
The fabricator/manufacturer/facility nameVulcan Materials-Sun Valley Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number220831 SVa MPC A detailed description of where the material sample was collectedBelt Cut at Vulcan Sun Valley
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID
Test Details
DIME Sample ID: 2020-09-21-27
DIME Test ID: 2020-09-21-27-6
Testing Lab: CT - Southern Regional Laboratory
Test Method: AASHTO T176-08: Standard Method of Test for Plastic Fines in Graded Aggregates and Soils by Use of the Sand Equivalent Test (Sand Equivalent)
Test Release Date: 2020-09-30
Test Results

How many times will the test be run?: 3 Times
Input Type: Measured
Tester's full name: Satish Jain
Date of test: 09/29/2020
Clay Level (Test 1): 5.4
Sand Level (Test 1): 3.9
Clay Level (Test 2): 5.5
Sand Level (Test 2): 3.9
Clay Level (Test 3): 5.8
Sand Level (Test 3): 4
Sand Equivalent (Test 1): 73
Sand Equivalent (Test 2): 71
Sand Equivalent (Test 3): 69
Sand Equivalent:71
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 09/30/2020