Test 2020-09-14-31-3 (AASHTO T315-16) Summary

Project Information
Project IdentifiersProject ID: 215135
DEA: 061A8304
EFIS: 0620000082
MINOR: 06A2629
DIST-CO-RTE-PM06---
Work DescriptionNot set
Location DescriptionNot set
Sample Information
Sample Taken Date9/14/2020 Sample Unique Key31
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing9/23/2020
Sample typeAcceptance A brief description of the sampleAB #1 Test, #2(816119), #3(057039), #4(816120) No test
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byvulcan materials Last name of sampler or witnessed byVulcan Materials
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility namevulcan materials Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Binder Performance GradePG 64-10
ModifiedNo Lot number
Sublot number Tank numberNot set
Time of sampleNot set HMA SupplierNot set
Asphalt Binder SupplierNot set MultigradeNot set
Multigrade TypeNot set HMA Design ID
Test Details
DIME Sample ID: 2020-09-14-31
DIME Test ID: 2020-09-14-31-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-16: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2020-09-30
Test Results

Phase: Original binder
Input Type: Measured
Tester's full name: DOUG RUFF
Date of test: 09/28/2020
Test Plate Diameter: 25 mm
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.170 kPa
Phase Angle (δ) (for the 10 cycles): 89.5 degree
Complex Modulus (G*) (for the 10 measurements): 1.420 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 1.42 kPa
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 09/30/2020