Summary for Test 2020-08-17-27-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214388 DEA: 051F6804 EFIS: 0514000046 |
---|---|
DIST-CO-RTE-PM | 05-MON-1-39.8/74.6 |
Award Date | 11/05/2019 |
Closeout Date | 08/17/2022 |
Work Description | RHMA OVERLAY ON EXISTING ROADWAY AND REPLACE GUARDRAIL. |
Location Description | MONTEREY COUNTY FROM TORRE CANYON BRIDGE NEAR BIG SUR TO SAN LUIS AVENUE IN CARMEL |
QA Service Level | 1 (Verified on 09/06/2019) |
Sample Information
Sample Taken Date | 08/17/2020 | Sample Unique Key | 27 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/27/2020 |
Sample type | Verification | A brief description of the sample | Boxes of RHMA-G |
The quantity of what the sample constitutes | One JMF Renewal | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | J | Last name of sampler or witnessed by | Gomez |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Graniterock Aromas Batch | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-08-17-27
DIME Test ID: 2020-08-17-27-1
Testing Lab: CT D05 - San Luis Obispo District Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-08-31
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Field Lab
Date of test: 08/17/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1506.7 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.43 %
Moisture Content: no data %
Temperature Compensation Factor: no data
Test Temperature: no data F
Corrected Asphalt Binder Content: 7.45 %
General comments (publicly viewable) (Max 1000 characters): D5 lab correction factor is 0.69. 0.43 is field lab correction factor.
Test was verified on 8/31/2020 ✔