Summary for Test 2020-06-10-40-3
Test performed: AASHTO T312-14Project Information
Project Identifiers | Project ID: 212866 DEA: 021H9704 EFIS: 0216000051 |
---|---|
DIST-CO-RTE-PM | 02-TEH-36-12.6/13.1 |
Award Date | 11/25/2019 |
Closeout Date | 10/06/2020 |
Work Description | CURVE REALIGNMENT AND HMA PAVING. |
Location Description | TEHAMA COUNTY ABOUT 16 MILES EAST OF PLATINA FROM 2.3 MILES EAST TO 2.8 MILES EAST OF DRY CREEK BRIDGE |
QA Service Level | 1 (Verified on 01/08/2019) |
Sample Information
Sample Taken Date | 06/10/2020 | Sample Unique Key | 40 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/10/2020 |
Sample type | Verification | A brief description of the sample | 3/4-inch Type A HMA (eq. PG 64-28 M) 22.0 RAP, 1.2 Lime |
The quantity of what the sample constitutes | JMF Renewal and PSE | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Dave | Last name of sampler or witnessed by | Lockett |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78461 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Northstate Asphalt, Redding, CA | Transportation Laboratory (TL) Number | 736618 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | Not set |
Test Details
DIME Sample ID: 2020-06-10-40
DIME Test ID: 2020-06-10-40-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T312-14: Preparing and Determining the Density of Asphalt Mixture Specimens by Means of the Superpave Gyratory Compactor (Method of Compaction)
Test Release Date: 2020-08-31
Test Results
HMA Type: Type A HMA
Is this test used for JMF verification:
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 06/11/2020
Start time of test (military time): 0843
Specimen identification: 2061101
Percent Binder Content: 4.9 %
Average diameter of the mold: 150 mm
Height of the extruded specimen (Hm): 116.3 mm
Mass of the specimen: 4792.4 g
Maximum Specific Gravity (Gmm): 2.508
Bulk Specific Gravity (Gmb): 2.429
Unit weight of water: 1 g/cm^3
Gyration Angle: 1.16 deg
Gyration Angle: 20.2 mrad
Method used to verify gyration angle: AASHTO T 344 at room temperature
Uncorrected relative density (Gmmu8): 83.1 %
Uncorrected relative density (Gmmu85): 91.8 %
Uncorrected relative density (Gmmu130): 93.0 %
Air Voids (AV8): 13.5 %
Air Voids (AV85): 4.4 %
Air Voids (AV130): 3.1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/31/2020 ✔