Summary for Test 2020-07-13-25-4
Test performed: ASTM C1038-14bProject Information
Project Identifiers | Project ID: 213811 DEA: 112T2184 EFIS: 1116000174 |
---|---|
DIST-CO-RTE-PM | 11-SD-5-R38.4/R47.3 |
Award Date | 10/29/2018 |
Closeout Date | 01/03/2024 |
Work Description | (Alternative Delivery) Construct HOV lanes, soundwalls, culvert rehab, ITS, and bike trail on I-5 . NCC I-5 Highway Improvement. |
Location Description | IN SAN DIEGO COUNTY IN ENCINITAS AND CARLSBAD FROM SAN ELIJO LAGOON BRIDGE TO 0.3 MILE NORTH OF PALOMAR AIRPORT ROAD OVERCROSSING. |
QA Service Level | 1 (Verified on 12/19/2018) |
Sample Information
Sample Taken Date | 07/13/2020 | Sample Unique Key | 25 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/13/2020 |
Sample type | Quality Assurance | A brief description of the sample | Rapid Setting Cement |
The quantity of what the sample constitutes | 1 bag | From where was the sample collected | Job Site |
First name of sampler or witnessed by | na | Last name of sampler or witnessed by | na |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | CM204001 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | C-MAX | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Cementitious | Brand | CMAX |
---|---|---|---|
Mill | Unknown | Type of Cementitious Material | Rapid Set Cement |
Test Details
DIME Sample ID: 2020-07-13-25
DIME Test ID: 2020-07-13-25-4
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Test Release Date: 2020-08-17
Test Results
Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 08/17/2020
Specimen A Initial measurement at 24 hours: 0.2976 in
Specimen B Initial measurement at 24 hours: 0.2979 in
Specimen C Initial measurement at 24 hours: 0.2671 in
Specimen D Initial measurement at 24 hours: 0.263 in
Specimen A Final measurement at 14 days: 0.2977 in
Specimen B Final measurement at 14 days: 0.298 in
Specimen C Final measurement at 14 days: 0.2673 in
Specimen D Final measurement at 14 days: 0.2631 in
The average length of change of the four specimens: 0.001 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/17/2020 ✔