Summary for Test 2020-07-24-6-5

Test performed: ASTM C1038-14b

Project Information

Project IdentifiersProject ID: 214843
DEA: 060X6704
EFIS: 0618000229
DIST-CO-RTE-PM06-TUL-63,65,99,190,198-Var
Award Date05/14/2020
Closeout Date07/15/2021
Work DescriptionREPLACE BRIDGE DECK WITH POLYESTER CONCRETE OVERLAY & PLACE CONCRETE.
Location DescriptionTULARE COUNTY AT VARIOUS LOCATIONS
QA Service Level1 (Verified on 04/20/2020)

Sample Information

Sample Taken Date07/24/2020 Sample Unique Key6
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/24/2020
Sample typePreliminary A brief description of the sampleRapid Setting Cement
The quantity of what the sample constitutes1 Bucket From where was the sample collectedJob Site
First name of sampler or witnessed byna Last name of sampler or witnessed byna
Title of sampler Telephone number of sampler
Laboratory sample identificationCM204002 Linked DIME Sample ID
The fabricator/manufacturer/facility nameCTS Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeCementitious BrandCTS
MillJuarez Type of Cementitious MaterialRapid Set Cement

Test Details

DIME Sample ID: 2020-07-24-6
DIME Test ID: 2020-07-24-6-5
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C1038-14b: Standard Test Method for Expansion of Hydraulic Cement Mortar Bars Stored in Water (Cement Mortar Bars)
Test Release Date: 2020-08-13

Test Results


Input Type: Measured
Tester's full name: Benjamin Lenz
Date of test: 08/10/2020
Specimen A Initial measurement at 24 hours: 0.3288 in
Specimen B Initial measurement at 24 hours: 0.2578 in
Specimen C Initial measurement at 24 hours: 0.3158 in
Specimen D Initial measurement at 24 hours: 0.2798 in
Specimen A Final measurement at 14 days: 0.3294 in
Specimen B Final measurement at 14 days: 0.2583 in
Specimen C Final measurement at 14 days: 0.3162 in
Specimen D Final measurement at 14 days: 0.2804 in
The average length of change of the four specimens: 0.005 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/13/2020