Test 2020-07-22-16-3 (ASTM D36-14ε1) Summary

Project Information
Project IdentifiersProject ID: 213733
DEA: 051C85U4
EFIS: 0518000156
DIST-CO-RTE-PM05-SCR-1-10.2/17.5
Work DescriptionSanta Cruz 1 CAPM and Bridge Rails
Location DescriptionSANTA CRUZ COUNTY IN AND NEAR SANTA CRUZ FROM NORTH APTOS UNDERPASS TO JUNCTION ROUTE 9.
Sample Information
Sample Taken Date7/22/2020 Sample Unique Key16
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/28/2020
Sample typeAcceptance A brief description of the sampleRubber Asphalt Binder
The quantity of what the sample constitutes1 can, #15 TEST From where was the sample collectedSource
First name of sampler or witnessed byD Last name of sampler or witnessed byEvans
Title of samplerQC Laboratory sample identification
The fabricator/manufacturer/facility nameSan Joaquin Refinery Transportation Laboratory (TL) Number842895
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAsphalt Rubber Binder Asphalt modifier supplier
Performance GradePG 64-16 Lot number1
Sublot number81 HMA Design ID
Test Details
DIME Sample ID: 2020-07-22-16
DIME Test ID: 2020-07-22-16-3
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: ASTM D36-14ε1: Standard Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus) (Softening Point)
Test Release Date: 2020-07-31
Test Results

ASTM Thermometer used?: 15C
Input Type: Measured
Tester's full name: Juan Gomez
Date of test: 07/31/2020
Bath Liquid: freshly boiled distilled water
General comments (publicly viewable) (Max 250 characters):

Test was verified on 07/31/2020