Test 2020-07-13-3-8 (AASHTO T84-14) Summary

Project Information
Project IdentifiersProject ID: 66667
DEA: JMFPP
EFIS: 0019000043
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for JMF Prequalification Program.
Location DescriptionNot set
Sample Information
Sample Taken Date7/13/2020 Sample Unique Key3
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing7/13/2020
Sample typeVerification A brief description of the sampleUntreated aggregate blend
The quantity of what the sample constitutes6 bags From where was the sample collectedSource
First name of sampler or witnessed byTrenton Last name of sampler or witnessed byCrouse
Title of samplerLab Manager Laboratory sample identification20-HMA-0115
The fabricator/manufacturer/facility nameTeichert Materials Tracy Transportation Laboratory (TL) NumberC827327
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-39-0021
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size3/4 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2020-169
Test Details
DIME Sample ID: 2020-07-13-3
DIME Test ID: 2020-07-13-3-8
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2020-07-21
Test Results

Input Type: Measured
Tester's full name: Ryan Kester
Date of test: 07/16/2020
Mass of saturated surface dry sample (before pycnometer) (S): 500.8 grams
Mass of the pycnometer with water and aggregate (C): 986.5 grams
Mass of the pycnometer with water (B): 678 grams
Mass of the oven dried sample (before pycnometer) (A): 490.2 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500.8 grams
Mass of the oven dry aggregate (for absorption) (A): 490.2 grams
Test Sample Preparation: Total Saturation
Bulk specific gravity:2.549
Bulk specific gravity (SSD Basis):2.604
Apparent specific gravity:2.698
Absorption:2.2 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/21/2020