Test 2020-07-06-22-3 (AASHTO T96-02r10) Summary

Project Information
Project IdentifiersProject ID: 214732
DEA: 051M5004
EFIS: 0519000166
DIST-CO-RTE-PM05-SB-166-0.2/6.9
Work DescriptionCOLD PLANE EXISTING ROADWAY AND PLACE RHMA-G.
Location DescriptionSANTA BARBARA COUNTY IN AND NEAR GUADALUPE AND SANTA MARIA FROM OBISPO STREET TO BLOSSER ROAD
Sample Information
Sample Taken Date7/6/2020 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing7/14/2020
Sample typeVerification A brief description of the sampleBags of Aggregate
The quantity of what the sample constitutesOne JMF Renewal From where was the sample collectedManufacturer
First name of sampler or witnessed byNot Last name of sampler or witnessed byGiven
Title of sampler Laboratory sample identification
The fabricator/manufacturer/facility nameCalPortland Garey Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-42-0014
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedAt the Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number JMF Verification ID JMF3513-2020-159
Test Details
DIME Sample ID: 2020-07-06-22
DIME Test ID: 2020-07-06-22-3
Testing Lab: CT D05 - Field Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2020-07-15
Test Results

Input Type: Calculated
Tester's full name: 3513
Date of test: 09/11/2019
Grading designation: C
Percent loss after 100 revolutions:6 %
Percent loss after 500 revolutions:31 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 07/15/2020