Summary for Test 2020-05-21-37-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 214725 DEA: 020J1304 EFIS: 0219000064 |
---|---|
DIST-CO-RTE-PM | 02-LAS-139-43.0/53.0 |
Award Date | 04/10/2020 |
Closeout Date | 10/06/2020 |
Work Description | COLD IN-PLACE RECYCLING AND PLACE HMA (TYPE A). |
Location Description | LASSEN COUNTY ABOUT 42 MILES NORTH OF SUSANVILLE FROM 3.8 MILES NORTH OF SLATE CREEK TO 4.7 MILES SOUTH OF WILLOW CREEK RANCH ROAD |
QA Service Level | 1 (Verified on 03/02/2020) |
Sample Information
Sample Taken Date | 05/21/2020 | Sample Unique Key | 37 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 05/22/2020 |
Sample type | Verification | A brief description of the sample | Fine RAP |
The quantity of what the sample constitutes | JMF Verification Renewal | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Jimmy | Last name of sampler or witnessed by | Montana |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | D78438B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Shaw Pit Facility | Transportation Laboratory (TL) Number | 733196 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Shaw Pit Facility |
---|---|---|---|
Aggregate Size | 3/8-inch | Aggregate Source | |
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number | Not set |
Test Details
DIME Sample ID: 2020-05-21-37
DIME Test ID: 2020-05-21-37-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2020-07-16
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Calculated
Tester's full name: Ward Jenkins
Date of test: 05/23/2020
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1502.2 g
Mass Loss: no data
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: no data
Test Temperature: 1000 F
Corrected Asphalt Binder Content: 6.77 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 7/16/2020 ✔