Test 2020-03-12-28-2 (CTM 217-June 2011) Summary

Project Information
Project IdentifiersProject ID: 66666
DEA: APP
EFIS: 0019000052
DIST-CO-RTE-PM59---
Work DescriptionSpecial project for submitting Sample information for Aggregate Pre-approval Program (APP). Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
Sample Information
Sample Taken Date3/12/2020 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing3/12/2020
Sample typeAggregate Prequalification Program A brief description of the sampleWashed Concrete Sand
The quantity of what the sample constitutes3 Sample Bags From where was the sample collectedSource
First name of sampler or witnessed byMarc Last name of sampler or witnessed bySegura
Title of samplerQC Representative Laboratory sample identificationCemex-Redlands-WCS
The fabricator/manufacturer/facility nameCemex - Redlands Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-36-0068
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant number4420 A detailed description of where the material sample was collectedPlant Stockpile
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Sizefine
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2020-03-12-28
DIME Test ID: 2020-03-12-28-2
Testing Lab: Cemex - Central & Southern California
Test Method: CTM 217-June 2011: Method of Test for Sand Equivalent
Test Release Date: 2020-07-06
Test Results

Number of tests: 3
Input Type: Calculated
Tester's full name: Marc Segura
Date of test: 03/12/2020
Temperature correction:71
Temperature of solution:71
Clay reading (test 1):2.9
Sand reading (test 1):2.4
Clay reading (test 2):2.8
Sand reading (test 2):2.3
Clay reading (test 3):3
Sand reading (test 3):2.5
Sand equivalent (test 1):83
Sand equivalent (test 2):82
Sand equivalent (test 3):84
Sand equivalent before temperature correction:83
Sand equivalent after temperature correction:83
General comments (publicly viewable) (Max 1000 characters): CEMEX-REDLANDS-PLANT #4420 DIME SAMPLE ID# 2020-03-11-23

Test was verified on 07/06/2020