Test 2020-05-31-9-6 (CTM 202-November 2011) Summary

Project Information
Project IdentifiersProject ID: 213970
DEA: 080K1214
EFIS: 0815000245
DIST-CO-RTE-PM08-SBD-15-12.5/14.8
Work DescriptionREPLACE PCC PAVEMENT WITH JPCP AND PRECAST JOINTED CONCRETE PAVEMENT.
Location DescriptionSAN BERNARDINO COUNTY IN FONTANA AND NEAR DEVORE FROM 0.3 MILE SOUTH OF SIERRA AVENUE UNDERCROSSING TO GLEN HELEN PARKWAY UNDERCROSSING
Sample Information
Sample Taken Date5/31/2020 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing6/2/2020
Sample typeAnnual Source Testing A brief description of the sample3/8" X No.8 PCC Aggregate
The quantity of what the sample constitutes5 Bags From where was the sample collectedSource
First name of sampler or witnessed byChris Last name of sampler or witnessed byHindman
Title of samplerQC Technician Laboratory sample identification1152
The fabricator/manufacturer/facility nameRobertsons-Rialto Transportation Laboratory (TL) Number1152
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name
Material Information
Material TypeAggregate Source Identification (SMARA or name of Pit)91-36-0146
The fabricator's/manufacturer's product name for the sampleUnknown The fabricator/manufacturer designation for the sampleUnknown
The plant numberUnknown A detailed description of where the material sample was collectedRobertson Rialto
Where the material sample would have been placed if not sampledUnknown Primary Aggregate Nominal Size3/8 inch
The concrete mix design numberUnknown Lot numberUnknown
Sublot numberUnknown HMA Design ID
Test Details
DIME Sample ID: 2020-05-31-9
DIME Test ID: 2020-05-31-9-6
Testing Lab: CT - Southern Regional Laboratory
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2020-06-29
Test Results

What size aggregate is being tested?: 0.375 in x No. 8 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Input Type: Calculated
Tester's full name: Domoinic Montemayor
Date of test: 06/11/2020
Cumulative percent passing the 1/2 in. sieve:100 %
Cumulative percent passing the 3/8 in. sieve:95 %
Cumulative percent passing the #4 sieve:23 %
Cumulative percent passing the #8 sieve:6 %
General comments (publicly viewable) (Max 250 characters):

Test was verified on 06/29/2020